Tender For set up of lecture recording studio - equipments as per nit, sitc of camera, sitc of ptz camera ceiling mount system, sitc of hd 8-channel digital video switcher, sitc of video streaming encoder, sitc of recorder, sitc of up down cross converter, sitc of 75 intarective display with ops kit, sitc of full hd ips 24" interactive pen display unit, sitc of 16" (40.64cm) 10-point touch screen monitor, sitc of 50 inch, uh display with wall mount kit, sitc of 32 inch, uh display, sitc of 24 inch, full hd 1920 x 1080,ips panel, sitc of multiplatfrom vc iniciater enginin, sitc of desktop system for editing, sitc of abobe cc all apps education subcription for 3 yrs subscription, sitc of hdmi to usb 3 capture device, sitc of 12 channel audio mixer, sitc of 4.5 " compact desktop reference monitor, sitc of earphone, sitc of all in one digital wireless lavalier microphone, sitc of all in one digital wireless handheld microphone, sitc of dynamic vocal microphonestand, sitc of dynamic vocal microphonestand, sitc of das storage, 8-bay hardware raid enclosure, sitc of 160w led soft studio light, sitc of 4 leaf barndoor, sitc of 80w led soft studio light, sitc of 80w led soft studio light, sitc of accessories for all the lighting fixtures, sitc of lighting grid or ceiling mount, 1024 mini dmx 512 stage lighting controller, sitc of power control system, sitc of digital dimming system, sitc of wiring of studio, sitc of 3 in 1 motorized background support system with croma screen for croma set, sitc of 3 in 1 motorized background support system with croma screen for croma set, sitc of 18u full loaded 600x800 rack with pdu, installation materials, system integration, commissioning, operation & maintenance training, part a- supply of vrf equipment, supply of inverter type variable refrigerant flow system - a . 5 hp side discharge, supply of variable refrigerant flow type indoor unit, supply of four way cassette ac - 1.5 tr, supply of hi wall split ac - 1.0 tr, refjoints, cordless controller, part b- supply of low side items & installation, testing & commissioning of the vrf system, nstallation, testing and commissioning of the above vrf outdoor units ..5 hp side discharge, installation, testing and commissioning of the above vrf indoor units .hi wall split ac - 1.0 tr, installation, testing and commissioning of the above vrf indoor units four way cassette ac - 1.5 tr, supply, installation, testing and commissioning of cu. refrigerant pipes (requried as per oem design) duly insulated with 19mm / 13mm close cell elastometric nitrite rubber insulation between each set of outdoor and indoor units (vrf), supply, installation, testing and commissioning of pvc pipe medium class (for drainage of water from idu) with 6 mm thick nitrile rubber insulation., supply & laying of cu conductor scheilded flexible communication cabling between odu and idu as per oem specification (vrf). cable shall be laying through hard pvc conduit pipe, ms structure, supply & filling of first charge of refrigerant r410a, lifting & shifting charges, scaffolding charges, training cost (for a period of six months)
Tender For design, manufacturing, supply, testing & commissioning of 7.0m height aluminium scaffolding ladder suitable for 45t capacity motorised eot crane located in generator floor at shiva hes.
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2); contract for network arc of trombay unit- 1 12 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, mtr 3000, 2 24 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, no 2000, 3 lc-sc single mode 9/125 duplex fibre patch cord of minimum 2 meter length, make:, dlink/ digilink/molex/tyco/amp/systimax/r&m/panduit or equivalent, no 50, 4 utp cat 5e cable ( 300 meter box), make: dlink/ digilink/ tyco/ amp/ systimax/, r&m/panduit/rit or equivalent, no 70, 5 modular type cat 5e wall mount information outlet with one rj 45 port and box,, make: dlink/digilink/tyco/ amp/systimax/ r&m/ panduit /rit or equivalent, no 1000, 6 cat 5e rj 45 jacks (1 box of 100 nos. connectors), make: dlink/digilink /molex/tyco, /amp/ systimax/ r&m/ panduit/rit or equivalent, no 50, 7 utp cat 6 cable ( 300 meter box), make: dlink/digilink /molex/tyco /amp /systimax/, r&m/panduit/rit or equivalent, no 20, 8 1 inch pvc casing caping 1 conduit, t -joint accessories, couplers etc. for fixing, isi, make, mtr 1000, 9 6 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 10 9 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 11 outdoor water proof underground enclosure box for ofc splicing of 24 core splicing,, make: raycaum / mx or equivalent, no 100, 12 wifi extender repeater signal booster, 300mbps make: dlink or equivalent no 20, sr item description in supply uom estimated, qty, 13 underground digging 2 feet deep in soft soil, backfilling for restoration to original, state, mtr 4000, 14 underground digging 2 feet deep in hard soil, & backfilling for restoration to original, state, mtr 1000, 15 underground digging 2 feet deep in tar road & backfilling for restoration to original, state, mtr 500, 16 underground digging 2 feet deep in concrete & backfilling for restoration to original, state, mtr 500, 17 pulling of fo cables inside duct and laying in underground trench mtr 5000, 18 pulling of fo cables inside casing caping / conduits and saddling inside building mtr 3000, 19 pulling of utp cables inside duct and laying in underground trench mtr 2000, 20 pulling of utp cables inside casing caping / conduits and saddling inside building mtr 15000, 21 pulling of fo cables / utp cables inside duct and laying on existing cable tray of 15, feet hight from ground using scaffolding / articulate booms, mtr 3000, 22 termination of utp cat 5/6 cable in rj45 information outlet (i/o) / jacks, fixing of i/o, box on wall, no 2000, 23 otdr testing for fo cable core no 1000, 24 splicing of sm / mm fo cable cores in liu / enclosure box & dressing no 5000, 25 installation / mounting of 6u / 9u rack on wall no 25, 26 one no onsite manpower qtr 12.
Tender For supply of hpcl mundra terminal water tank repair works : : -dismantling of structural steel , supply of steel plates , fabrication of steel plates , supply and fabrication structural steel , supply and erection grating , supply and fab overflow nozzle 80 nb , supply and fab inlet nozzle 80 nb , double scaffolding , bottom shell plate testing , tank box up , slag blasting , zinc silicate primer 1 coat , internal tank painting , external tank painting , painting of hp logo , letter painting , supply and install 24 inch gate valve , bottom cleaning
Tender For supply of machine tools and equipments under frampo scheme - machine tools & equipment, lot-i, 5 axis cnc milling machine, lot-ii, digital ultrasonic testing machine, digital vickers hardness test, surfaceroughnesstester, electronic universal testing machine, lot -iii, work station for lab, lot-iv, xrf machine, lot-v, creep testing machine
Tender For design, manufacture, testing, supply and installation/demonstration of 01 set of insulated aerial work platform mounted on a vehicle, insulated scaffolding system, sky ladder vehicle, tools transportation vehicle along with 400kv hot line maintenance tools-138 items for hot/live line maintenance system for transmission lines & substations upto 400kv voltage class required at hotline sub-division, kptcl, shivamogga conforming to kptcl technical specification along with annual maintenance contract for a period of five years